STEP 2 OF 7 — PLOT CONFIGURATION

Configure your plot

Enter your plot dimensions, location, and structural parameters. Graham uses IS 456:2000, IS 1893:2016, and IS 875 Part 3 with local authority bylaws to generate compliant designs.

PLOT DIMENSIONS
Plot Area
30×60 ft
Sqft
1,800 sqft
Sq.m
167.2 m²
COMMON PRESETS (FT)
PLOT FACING / ROAD SIDE
North-facing — Excellent — prosperity & positive energy
CITY & LOCAL AUTHORITY
🏛️
Authority
DDA / MCD
📋
Bylaws
MPD-2021
🌍
Seismic Zone
Zone IV — High
💨
Wind (IS 875)
Vb = 47 m/s
📐
Max FAR
1.5 – 4.0
🏢
Max Floors
G+3
📏
Front Setback
3m
📏
Side Setback
1.5m
STRUCTURAL PARAMETERS — IS 456:2000
IS 456 Cl.39.3 · Pu = 0.4 fck·Ac + 0.67 fy·Asc · Working load = Pu/1.5 @ 1% steel
SITE CONDITIONS — IS 1893:2016
DERIVED PARAMETERS
Zone Factor Z
0.24
IS 1893 Table 2
Design Coeff. Ah
0.12
IS 1893 Cl.6.4.2
Wind Pressure pz
1.273 kN/m²
IS 875 Part 3
Col. Capacity
467 kN
230mm M25
Max FAR
4
DDA / MCD
Max Floors
G+3
DDA / MCD
Front Setback
3 m
DDA / MCD
Max Coverage
50%
DDA / MCD
CONFIGURED PLOT SUMMARY
30×60 ft · 1,800 sqft (167.2 m²) · N-facing
Delhi (NCT) · M25/Fe500 · 230mm cols (467 kN) · Zone IV